5515 Digital Ceiling Emitter
Simco-Ion’s Model 5515 Ceiling Emitter paired with Controller Models 5522 and 5582 forms a state-of-the-art digital room ionization system. The fully digital technology allows each ceiling emitter’s parameters including ion output, pulse timing, and digital address, to be precisely configured. These settings can be adjusted on-site using the Model 5571 and 5572 handheld controllers, or remotely through IonManager Pro software for centralized management. Precision fine-tuning of each emitter ensures optimal ionization performance under any airflow conditions and for every specific application.The system features single-crystal silicon or titanium emitter points and incorporates advanced feedback technology to maintain consistent ion output. Small and large capacity controllers provide flexible options for spaces of varying sizes, making this solution ideal for environments that demand precise, reliable, and efficient static charge control.
Specifications
| Voltage | Input: 24 VAC, 50/60 Hz, 1W (typ) Output: 0-20 kVDC for each polarity; positive and negative output levels adjusted separately |
| Ion Emission | Pulsed DC, Steady-state DC, or Standby |
| Emitter | Single-crystal Silicon or Titanium, replaceable |
| Emitter Rod | 2.5, 5, 7.5, 10, 15, 24, 36, 48, 60, 66 inch (6.35, 12.7, 19.1, 25.4, 38.1, 61.0, 91.4, 122, 152, 168 cm), custom lengths are available |
| Cleanroom Class | Single-crystal Silicon ISO 14644-1 Class 1 or Titanium ISO 14644-1 Class 3 |
| Connector | Telephone-type RJ-11 modular jack receptacle on each end of emitter |
| Control Signal | Ionization parameters are adjusted with the 5571 Handheld Terminal, 5572 IR Remote, or via IonManager Pro software |
| Timing | Precise timing (0-10 sec @ 0.1 sec resolution) is generated by a local microcontroller; LEDs on each emitter indicate the polarity of the ion emission |
| Regulation | Output and balance stability is achieved by independently regulating the ion emission current of each polarity at each emitter |
| Alarm | Alarm operates when emitter is no longer able to maintain preset ion output level; visual LED in the middle of the emitter; optional audible alarm at controller |
| Ozone | <0.005 ppm |
| Operating Env | 59-95˚F (15-35˚C) nominal; 20-60% RH, non-condensing |
| Dimension | 1.2”H x 1.4”W x 17.5”L (3.05 x 3.56 x 44.5 cm) |
| Weight | 1.03 lb (0.465 kg) |
| Warranty | 10-year limited warranty |