Bioaerosol Monitoring System with real-time data for microbial monitoring

PMT® BioAerosol Monitoring System

The BioAerosol Monitoring System (BAMS) M120 is an advanced real-time airborne microbial monitoring solution designed for high-performance cleanroom and controlled environment applications. Engineered to meet strict pharmaceutical, biotechnology, and healthcare standards, it delivers continuous, instantaneous detection of bioaerosols without the need for incubation or traditional culture methods. With a precise flow rate of 2.83 LPM and particle size detection ranging from 0.5 to 25 µm, the M120 ensures accurate monitoring of airborne contamination. Its ISO 21501-4 compliant particle counting technology guarantees high measurement reliability, while integrated alarm functions provide immediate alerts when contamination thresholds are exceeded. The system supports 24/7 continuous monitoring and offers real-time data visualization, enabling fast decision-making, contamination control, and process optimization. Thanks to its portable design, lightweight structure, and robust 316L stainless steel and anodized aluminum enclosure, the M120 is suitable for both fixed installations and mobile operations. Equipped with multiple connectivity options including USB, RJ45, and optional WiFi, the system allows seamless data transfer and export in PDF or Excel formats. Its large internal storage capacity ensures secure long-term data recording, while user-level access management enhances data integrity and compliance. Ideal for pharmaceutical manufacturing, sterile production areas, laboratories, and healthcare environments, the BAMS M120 significantly improves contamination control, reduces production risk, and enhances quality assurance through continuous environmental monitoring and real-time microbial detection. BAMS met or exceeded all the acceptance criteria as outlined in USP <1223> for accuracy, precision, linearity, specificity, LOD, LOQ, range, ruggedness, and robustness – so is an accepted alternative method for Microbial Environmental Monitoring in a Grade A area.                                                      

  • Bio Fluorescent Particle Counter (BFPC)
  • Designed to sample in Grade A Isolators or clean rooms
  • Real-time, continuous bioburden monitoring
  • No reagents required
  • Immediate results via 21 CFR Part 11 compliant software
  • Regulations: USP Chapter <1223> for the Validation of Alternative Methods.

Specifications

Size range0.5µm to 25µm
Size channels0.5µm,1.0µm,2.0µm,3.0µm, 5.0µm,10.0µm
Laser sourceLong life laser
Size resolution<15% @ 0.5µm (meets ISO 21501-4)
Count efficiency

50%±20% for 0.5µm,100%±10% for >0.75µm 

(meets ISO 21501-4 and JIS B9921 )

Flow rate2.83LPM ±3%
Flow rate controlElectronic, automatic closed-loop
Sampling time10 seconds-168 hours
Delay0-99 hours 59 minutes 59 seconds
Cycles1000 samples on one location
Interval5 seconds-99 hours 59 minutes 59 seconds
Sampling modeManual, auto, cumulative count Σ/ differential count ∆ or concentration
Zero count<1count/5min
Concentration limit4,000,000 particles/ft³ @10% coincidence loss
ExhaustInternal HEPA filter (>99.999% @ 0.3µm)
Display8.0" LCD capacitive touch screen
LanguageEnglish
CommunicationRJ45, USB, SENSER-HUB, WIFI
AlarmAudible built-in alarm
Capture of biological contamination sampleConnect the BioAerosol Sampler(BAS) via WIFI/USB to collect the biological contamination sample in real time
ReportCompliant with ISO/EUGMP/CHINESEGMP/Fed Std
Export filePDF file or EXCEL file
Data storage119GB
Data securityAuthority management, authority level divide into admin, operator and supervisor
Data reliabilityCompliant with 21 CFR Part11
PrintAuto or Off-line
Dimensions (HxWxD)10(H) x 7.87 (W) x 10.39(D) in 255(H) x 200(W) x 264(D) mm (with handle and foot mat)
Weight12.8Ibs/5.8kg;14.9Ibs/6.8kg (incl. battery)
Enclosure316L Stainless Steel and anodized aluminum
PowerAC 100-240V, 50 Hz/60 Hz
Battery10.8V, 9000mAhX2, rechargeable lithium battery
Operating conditions

Temperature: 5°C-35°C/41°F-95°F

Relative humidity: 5-90%, non-condensing

Storage conditionsTemperature: 0°C-40°C/32°F-104°F Relative humidity: 5-90%, non-condensing
Calibration frequencyOnce a year
Warranty12 months (calculated from the date of product activation or six months after the date of manu facture, whichever comes first).
SafetyEN 61010-1:2010+A1:2019, EN 61326-1:2013, EN 61326-2:2:2013, EN 60825-1:2014, EN 61000-6-1:2007, EN 61000-6-3:2007+A1, EN 62311:2008, EN 62479: 2010