The BioAerosol Air Sampler (BAS) is an advanced microbial air sampler based on the Andersen impactor method, designed for the precise sampling of airborne microorganisms in a wide range of environments. The device provides high flow rate accuracy with three available options: 28.3 L/min ± 4%, 100 L/min ± 2.5%, and 200 L/min ± 3%. Its long battery life ensures reliable operation across various application scenarios. The BAS can operate for up to 10 hours at 28.3 L/min (16.98 m³) and 100 L/min (60 m³), while at 200 L/min, a runtime of up to 4 hours (48 m³) is possible. In addition, the BAS features advanced user management with multi-level access control, allowing user permissions to be customized according to individual requirements. The device offers flexible sampling options, supporting both standard and remote sampling with a sampling tube of up to 8 meters in length. For calibration purposes, the BioAerosol Air Sampler supports various types of flow meters. The device also complies with ISO 14698-1, making it a reliable choice for applications involving airborne microbial sampling.


Specifications

Flow rate28.3L/min ±4%; 100L/min ±2.5%; 200L/min ±3%
Flow rate controlBuilt-in mass flow meter
Sampling plan20,000 groups, 20,000 rooms, 500 locations for each room, up to 20,000 locations
Sampling volumes1-6000L
Delay0-23 hours 59 minutes 59 seconds
Cycles1-999 cycles
Interval00:00:00.5 seconds-23 hours 59 minutes 59 seconds
Sampling head

Φ0.32mm280 holes (28.3/min) | Φ0.60mm280 holes (100L/min) | Φ0.70mm*400 holes (200L/min) 

(Anodized aluminum, 316L stainless steel material available, customizable sampling head)

Isokinetic probe caliberΦ101.8mm
Weight / Dimensions2,7Kg (6.0lbs); Φ110 mm; H:202mm (without foot mat)
External surfaceAnodized aluminium
PowerAC 100-240V, 50 Hz/60 Hz
Battery

10.8V, 6800mAh rechargeable lithium battery Battery last ≥10 hours (28.3L/min) | 

Battery last ≥10 hours (100L/min) | Battery last ≥4 hours (200L/min)

CommunicationUSB, WIFI
Application extensionConnect with the Airborne Particle Counter (APC) and BioAerosol Monitoring System (BAMS) to collect contaminated samples in real time
Data storage20,000 sets of records
AlarmLED lighting and beep
Display4.3" capacitive touch screen
LanguageEnglish
Calibration frequencyAnnual calibration is recommended
Operating conditionsTemperature: 5°C-35°C (41°F-95°F), 5-90% RH non-condensing
Storage conditionsTemperature: 0°C-40°C(32°F-104°F), 5-95% RH non-condensing
SafetyEN 61010-1:2010+A1:2019, EN 61326-1:2013, EN IEC 61326-1:20121, EN 61000-6-1:2007, EN 61000-6-3:2007+A1
Warranty24 months (calculated from the date of product activation or six months after the date of manufacture, whichever comes first)